DIN Rail Mounted Timer - Model 730
Model 730-02-000
DIN Rail mounted timer
Features
- DIN Rail Mounted Timer
- Selectable Timing Ranges
- 24 - 240 V ac/dc 50/60 Hz.
- DIN EN 50022-35
- 2-Screw Mounting
- Test Facility
- Customised Labelling
Enclosure Specification
|
External Dimensions:
|
90 X 58 X17,5 DIN 43880
|
|
Case material:
|
PC with 10% OF, V-0 grey.
|
|
Temperature stability:
|
|
|
To UL 746b
|
95deg/C
|
|
To Vicat
|
|
|
DIN 53460/lSO
|
Method B - l40deg/C
|
|
To ISO/ R 75
|
Method A - l40deg/C
|
|
DIN 53461
|
Method B - l50deg/C
|
|
Temperatures for permanent operation according to specification of
manufacture:
|
125 to 140deg/C
|
|
Flame retardancy:
|
|
|
To UL 94: |
Class V-0 at 1,6mm wall thickness. |
|
To VDE 0304 |
Degree 11b |
|
Terminal material:
|
Steel strip, fire-tinned
|
|
Max. conductor size:
|
2 X 2,5 mm sq solid or
2 X 1,5mm sq stranded with end sleeves to DIN 46288
|
|
Type of terminals:
|
Captive plus-minus terminals screws with self-lifting connection washer M
3.5, bared wire length mm. 9mm.
|
|
Case fixing:
|
I - Snap mounting on top hat rail -DIN EN 50022-35
2 - Screw mounting, distance between M4- screws 90mm
|
|
External:
|
Leakage path >~ 4.0mm
|
|
Degree of protection:
|
Case 1P40, DIN 40050
terminals 1P20, DIN 40050
|
Electrical Specifications
|
Input voltage:
|
24-240V AC/DC 50/60 Hz
|
|
Current Consumption
|
4 mA Max
|
|
Operating Temp.
|
-10 to + 50 Deg.C
|
|
Switch Capacity
|
1 Amp
|
|
Inrush Current
|
10 Amps for IOmSEC
|
|
Switch Holding Voltage
|
400V
|
|
Duty Cycle
|
100%
|
|
Switch Life
|
3E8 operations
|
|
Repeat Accuracy
|
+ or - 1%
|
|
Timing Temp. Coefficient
|
+ or - 0.005% per Deg.C
|
|
Scale Accuracy
|
+ or - 10%
|
|
Reset / Test
|
Manual Switch
|
|
Indicators
|
LED's to indicate Phase
|
Every effort has been taken to ensure the accuracy of this specification.
However in order to maintain our technological lead we are continuously
improving our products which could, without notice result in amendments or
omissions to this specification. We cannot accept responsibility for damage,